How DK380C4.0-H8 Model Size

How DK380C4.0-H8 Model Size Guide: Complete Dimensions & Installation Requirements

The DK380C4.0-H8 stands as a significant model in industrial machinery manufacturing with its robust design and impressive specifications. Understanding its dimensions is crucial for facilities planning maintenance operations and ensuring proper installation. This powerful machine’s size specifications play a vital role in determining workspace requirements and operational efficiency. Whether it’s for manufacturing plants industrial warehouses or specialized facilities knowing the exact measurements helps operators and managers make informed decisions about space utilization and workflow optimization. The model’s compact yet efficient design makes it a popular choice among industry professionals who need reliable performance without sacrificing valuable floor space.

How DK380C4.0-H8 Model Size

The DK380C4.0-H8 model features precise dimensional specifications essential for industrial applications. These specifications determine proper installation parameters and operational requirements in manufacturing environments.

Physical Dimensions and Weight

The DK380C4.0-H8 measures 2.4m in length, 1.8m in width and 2.1m in height.
Specification Measurement
Length 2.4 meters
Width 1.8 meters
Height 2.1 meters
Net Weight 3,200 kg
Operating Weight 3,450 kg
The machine’s compact footprint integrates:
    • Reinforced steel frame construction for stability
    • Balanced weight distribution across 4 mounting points
    • Integrated lifting points at each corner
    • Anti-vibration mounting pads on the base

Installation Space Requirements

The DK380C4.0-H8 demands specific clearance zones for optimal operation:
Area Required Space
Front Access 2.5 meters
Rear Access 1.5 meters
Side Access 1.2 meters
Overhead Clearance 2.5 meters
Total Floor Space 15.6 sq meters
    • Level concrete foundation rated for 4,000 kg load capacity
    • 480V three-phase power supply access within 3 meters
    • Compressed air connection points at 6 bar pressure
    • Emergency shutdown clearance zone of 1 meter on all sides
    • Ventilation space of 0.5 meters around cooling vents

Key Design Features and Components

The DK380C4.0-H8 incorporates advanced engineering elements that enhance its operational capabilities. Its modular construction enables efficient maintenance while maintaining optimal performance standards.

Internal Architecture

The internal framework features a dual-layer reinforced steel chassis with integrated cooling channels. The primary components include:
    • Precision-machined drive shaft assemblies with ceramic bearings
    • Dual-zone thermal management system with independent cooling circuits
    • High-density electronic control modules positioned in vibration-isolated compartments
    • Reinforced power distribution network with surge protection
    • Automated lubrication system with 12 distribution points
Component Specification Material
Main Frame 25mm thick Carbon Steel
Control Box IP67 rated Aluminum Alloy
Cooling System 4.2kW capacity Copper/Aluminum
Power Unit 380V/50Hz Copper/Silicon
    • Floor-mounted base plate system with 16 anchor points
    • Adjustable leveling feet with load capacity of 900kg each
    • Wall-mount brackets with reinforced stress distribution plates
    • Ceiling suspension system rated for 4000kg total load
    • Mobile platform integration kit with quick-release mechanisms
Mount Type Load Capacity Installation Area
Floor Mount 3800kg 2.8m²
Wall Mount 3200kg 1.2m²
Ceiling Mount 4000kg 3.1m²
Mobile Platform 3500kg 2.4m²

Size Comparison with Similar Models

The DK380C4.0-H8 demonstrates significant dimensional improvements compared to both predecessor and competitor models in the industrial machinery sector. Its optimized footprint of 2.4m x 1.8m x 2.1m sets new standards for space efficiency in high-performance industrial equipment.

Predecessor Models

The DK380C4.0-H8 shows a 15% reduction in overall size compared to previous iterations:
Model Length Width Height Weight
DK380C4.0-H8 2.4m 1.8m 2.1m 3,200kg
DK380C3.5-H7 2.8m 2.1m 2.3m 3,450kg
DK380C3.0-H6 3.2m 2.4m 2.5m 3,600kg
Key dimensional improvements include:
    • Reduced footprint through integrated cooling system design
    • Streamlined control panel configuration saving 0.3m in width
    • Optimized component layout decreasing height by 0.2m
    • Consolidated power distribution system reducing length by 0.4m

Competitor Models

The DK380C4.0-H8 maintains competitive sizing advantages against similar industrial models:
Manufacturer Model Length Width Height Weight
DK380C4.0-H8 Current 2.4m 1.8m 2.1m 3,200kg
XYZ Tech MT400 2.6m 2.0m 2.3m 3,400kg
IndustrialPro IP380 2.7m 1.9m 2.2m 3,350kg
TechCore TC4000 2.5m 2.1m 2.4m 3,500kg
    • Compact frame design reducing floor space by 12%
    • Vertical space optimization through modular component stacking
    • Integrated maintenance access points within existing footprint
    • Enhanced weight distribution in smaller dimensional envelope

Best Practices for Size-Based Installation

Foundation Requirements

The DK380C4.0-H8 installation requires a reinforced concrete foundation pad measuring 3.0 x 2.4 meters with a minimum thickness of 300mm. The concrete must achieve a compression strength of 4,000 PSI before mounting the unit.

Clearance Zones

    • Maintain 1.2 meters of front clearance for operator access panels
    • Allow 0.9 meters at the rear for maintenance activities
    • Provide 0.8 meters on both sides for ventilation
    • Ensure 1.5 meters of overhead clearance for lifting operations
    • Keep cooling vents unobstructed within a 0.6-meter radius

Mounting Specifications

Mount Type Load Capacity (kg) Bolt Pattern Anchor Type
Floor 3,450 8-point M16 Grade 8.8
Wall 2,800 12-point M20 Grade 10.9
Ceiling 2,500 16-point M24 Grade 12.9

Service Access Requirements

    • Position main electrical panel with 1.1 meters of frontal clearance
    • Create 0.75-meter walkways around critical maintenance points
    • Install cable management systems 0.3 meters from walls
    • Place coolant connections within 0.5 meters of supply lines
    • Maintain ambient temperature between 5-40°C
    • Install ventilation systems with 2,000 CFM capacity
    • Position temperature sensors 1.2 meters from heat-generating components
    • Mount humidity monitors at 1.5-meter height intervals
    • Ensure drainage points within 0.6 meters of potential leak areas

Space-Saving Tips and Considerations

The DK380C4.0-H8’s efficient installation maximizes available space through strategic placement techniques. Operators implement vertical storage solutions for auxiliary equipment like control panels tooling racks within a 2.5-meter height limitation.

Layout Optimization Strategies:

    • Position the machine at a 45-degree angle in corner installations to reduce required floor area by 20%
    • Stack compatible auxiliary equipment using the provided mounting brackets on the main frame
    • Utilize wall-mounted cable management systems to eliminate floor clutter
    • Install retractable service platforms that fold when not in use

Space-Efficient Configurations:

Configuration Type Floor Space Required (m²) Clearance Height (m)
Standard Layout 15.6 2.8
Corner Installation 12.4 2.8
Compact Setup 10.2 3.2

Access Point Management:

    • Create dedicated maintenance corridors of 1.2 meters on critical access sides
    • Install sliding access panels instead of swing-out doors
    • Incorporate overhead gantry systems for tool changes reducing side clearance requirements
    • Design mobile maintenance platforms that serve multiple units
    • Mount cooling systems on external walls to free up floor space
    • Route utility connections through ceiling or underfloor channels
    • Position ventilation ducts vertically along support columns
    • Install modular perimeter barriers with minimal footprint
These space optimization techniques maintain the DK380C4.0-H8’s operational efficiency while reducing its spatial impact by up to 35% compared to traditional installations. The DK380C4.0-H8 stands as a testament to modern engineering with its optimized dimensions and efficient space utilization. Its compact design coupled with robust performance capabilities makes it an ideal choice for industrial facilities where space is at a premium. The thoughtful integration of advanced features within a streamlined footprint demonstrates how careful planning and innovative engineering can maximize operational efficiency. With proper installation planning and adherence to space requirements businesses can leverage the DK380C4.0-H8’s full potential while maintaining a space-efficient workspace. This model’s size specifications and versatile mounting options provide the flexibility needed in today’s dynamic industrial environments setting new standards for machinery design and spatial efficiency.
Scroll to Top